Atlantic Waterway Design Loads

 
STUCTURE
Steel
FLOATS
Concrete/
Polyethylene
SERVICE LOADS
STANDARD
1.5KN/m²
SUPER
2.5KN/m²
FINGERS
1.0KN/m²

ENVIRONMENTAL LOADS

BASIC WIND SPEED
40 m/s
STEADY WIND SPEED
20 m/s
DESIGN PRESSURE
0.25KN/m²

WAVES

MAX SIGNIFICANT WAVE HEIGHT –  1YEAR  RETURN PERIOD
400mm